Unit | 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|---|
| Electric / Thermal Power output (MW) | 460 / 1380 | 784 / 2381 | 784 / 2381 | 784 / 2381 | 784 / 2381 | 1100 / 3293 |
| Type of Reactor | BWR-3 | BWR-4 | BWR-4 | BWR-4 | BWR-4 | BWR-5 |
| Operation Status at the earthquake occurred | In Service -> Shut - down | In Service -> Shut - down | In Service -> Shut - down | Out - age | Out - age | Out - age |
| Core and Fuel Integrity | Dama - ged (400) mostly | Dama - ged (548) 35% | Dama - ged (548) 30% | No fuel rods | Not Dama - ged (548) | Not Dama - ged (764) |
| Reactor Pressure Vessel Integrity | Dama - age & leak - age suspe - cted | Un- known | Un- known | Not Dama - ged | Not Dama - ged | Not Dama - ged |
| Containment Vessel Integrity | Dama - age & leak - age suspe - cted | Damage and leak Susp - ected | Not Dama - ged (estim - ation) | Not Dama - ged | Not Dama - ged | Not Dama - ged |
| Core cooling requiring AC power 1 | Not Funct - ional | Not Funct - ional | Not Funct - ional | N/A | Funct - ional | Funct - ional |
| Core cooling requiring AC power 2 | Not Funct - ional | Not Funct - ional | Not Funct - ional | N/A | Funct - ioning (in cold shut down) | Funct - ioning (in cold shut down) |
| Building Integrity | Severely Dama - ged | Partly open - ed | Severely Dama - ged | Severely Dama - ged | Open a vent - hole - to avoid hydro - gen explo - sion | Open a vent - hole - to avoid hydro - gen explo - sion |
| Water Level of the Rector Pressure Vessel | lower than bott - om of fuels | Fuel exposed | Fuel exposed | Safe | Safe | Safe |
| Pressure of the Reactor Pressure Vessel | Gradu - ally incre - asing / Gradu - ally decre - asing | Un- known / Stable | Un- known / Gradu - ally incre - asing | Safe | Safe | Safe |
| Containment Vessel Pressure | Decre - ased a little after incre - ase | Stable | Stable | Safe | Safe | Safe |
| Water injection to core | Cont. (Fresh - water) | Cont. (Fresh - water) | Cont. (Fresh - water) | N/A | N/A | N/A |
| Water injection to Containment Vessel (AM) | TBC | TBC (Sea water) | TBC | N/A | N/A | N/A |
| Containment venting (AM) | Temp stopped | Temp stopped | Temp stopped | N/A | N/A | N/A |
| Fuel Integrity in the spent fuel pool | Un- known (292) | Un- known (587) | Damage susp - ected (514) | Possibly Dama - ged (1331) | Not Dama - ged (946) | Not Dama - ged (876) |
| Cooling of the spent fuel pool | Water spray star -ted (fresh -water) | Cont. ( Switch to Fresh - water) | Cont. water spray and injec - tion (Fresh - water) | Water spray continue. Hydrogen from the pool exploded. Temp dec - reasing | Pool cooling capa - bility was recov - ered | Pool cooling capa - bility was recov - ered |
| Main Control Room Habitability & Operability | Poor due to loss of AC power | Poor due to loss of AC power | Poor due to loss of AC power | Poor due to loss of AC power | Not dam -aged (estimate) | Not dam -aged (estimate) |
| INES LEVEL (est by NISA) | 7 | 7 | 7 | 3 | - | - |
a little intro This blog is an attempt to relieve some stress from my life . Instead of screaming at C-Span and Cnbc to name a few i will now scream or talk to this blog.
Monday, May 23, 2011
Three level 7's @ Fukushima no U.S. media coverage!
Subscribe to:
Posts (Atom)