Monday, May 23, 2011

Three level 7's @ Fukushima no U.S. media coverage!

Fukushima nuclear power plant update - 20th May 2011

Click heading to sort - Download this data

Unit
1
2
3
4
5
6
Electric / Thermal Power output (MW)460 / 1380784 / 2381784 / 2381784 / 2381784 / 23811100 / 3293
Type of ReactorBWR-3BWR-4BWR-4BWR-4BWR-4BWR-5
Operation Status at the earthquake occurredIn Service -> Shut - downIn Service -> Shut - downIn Service -> Shut - downOut - ageOut - ageOut - age
Core and Fuel IntegrityDama - ged (400) mostlyDama - ged (548) 35%Dama - ged (548) 30%No fuel rodsNot Dama - ged (548)Not Dama - ged (764)
Reactor Pressure Vessel IntegrityDama - age & leak - age suspe - ctedUn- knownUn- knownNot Dama - gedNot Dama - gedNot Dama - ged
Containment Vessel IntegrityDama - age & leak - age suspe - ctedDamage and leak Susp - ectedNot Dama - ged (estim - ation)Not Dama - gedNot Dama - gedNot Dama - ged
Core cooling requiring AC power 1Not Funct - ionalNot Funct - ionalNot Funct - ionalN/AFunct - ionalFunct - ional
Core cooling requiring AC power 2Not Funct - ionalNot Funct - ionalNot Funct - ionalN/AFunct - ioning (in cold shut down)Funct - ioning (in cold shut down)
Building IntegritySeverely Dama - gedPartly open - edSeverely Dama - gedSeverely Dama - gedOpen a vent - hole - to avoid hydro - gen explo - sionOpen a vent - hole - to avoid hydro - gen explo - sion
Water Level of the Rector Pressure Vessellower than bott - om of fuelsFuel exposedFuel exposedSafeSafeSafe
Pressure of the Reactor Pressure VesselGradu - ally incre - asing / Gradu - ally decre - asingUn- known / StableUn- known / Gradu - ally incre - asingSafeSafeSafe
Containment Vessel PressureDecre - ased a little after incre - aseStableStableSafeSafeSafe
Water injection to coreCont. (Fresh - water)Cont. (Fresh - water)Cont. (Fresh - water)N/AN/AN/A
Water injection to Containment Vessel (AM)TBCTBC (Sea water)TBCN/AN/AN/A
Containment venting (AM)Temp stoppedTemp stoppedTemp stoppedN/AN/AN/A
Fuel Integrity in the spent fuel poolUn- known (292)Un- known (587)Damage susp - ected (514)Possibly Dama - ged (1331)Not Dama - ged (946)Not Dama - ged (876)
Cooling of the spent fuel poolWater spray star -ted (fresh -water)Cont. ( Switch to Fresh - water)Cont. water spray and injec - tion (Fresh - water)Water spray continue. Hydrogen from the pool exploded. Temp dec - reasingPool cooling capa - bility was recov - eredPool cooling capa - bility was recov - ered
Main Control Room Habitability & OperabilityPoor due to loss of AC powerPoor due to loss of AC powerPoor due to loss of AC powerPoor due to loss of AC powerNot dam -aged (estimate)Not dam -aged (estimate)
INES LEVEL (est by NISA)7773--